DESCRIPTION
nano dryers – D1 & D2 in detail
Patented combined filter & desiccant cartridges
- Built in inlet water separator (D1 only) eliminates the cost and pressure drop of installing a separate inlet filter in small oil-free compressor applications*
- Desiccant and outlet filtration are integrated into a single cartridge (eliminates the cost and pressure drop of installing separate filters)
- High density filled desiccant provides maximum adsorption capacity
- Easy to replace cartridges simplify maintenance requirements
PLC controlled operation
- The dryer is operated by a robust and reliable PLC control system offering valuable features including ‘power on’, ‘hours run’ and ‘service required’ indicators
- Memory retention built into the PLC enables the controller to pick up where it left off in the drying cycle, ensuring consistently clean and dry air downstream
- Compressor synchronization is a standard energy saving feature which starts and stops the dryer with a signal from the compressor or point-of-use equipment to eliminate purge loss when drying is not required
Energy saving dew point control option
- With this option, a dew point sensor is incorporated into the dryer providing the ultimate in energy savings
- The outlet dew point is constantly monitored allowing the cycle time to be adjusted depending on the actual moisture load - saving valuable purge air
- Dew point is conveniently displayed on the PLC
- The -ES option reduces valve actuation increasing service life and includes an extended 5-year valve warranty
Floor or wall installation
- Can be floor or wall mounted - simply by rotating the feet 90°
Optimum dew point performance
- Dryers are provided as standard set for a -40°F dew point. Optional dew points from -4°F to -94°F are available
- Air velocity and, therefore, air to desiccant contact time, is carefully controlled via a pressure maintaining device to ensure optimum dew point performance
Constant flow and pressure
- Pressure is equalized before switching columns to ensure uninterrupted compressed air and consistent air pressure. Equalization also ensures long desiccant life due to minimized desiccant attrition
Reliable high performance valves
- The NDL 010 to 050 use ball valves and two pilot operated solenoid valves for proven performance and reliability
- The NDL 060 to 090 use four pilot operated solenoid valves
- The NDL 100 to 130 use two integrated coaxial flow valves for inlet air and two pilot operated solenoid valves for exhaust
Maximum corrosion protection
- High tensile aluminum columns are alocromed then externally powder coated to provide maximum protection for corrosive environments