DESCRIPTION
Features
- Digital communication HART protocol
- High accuracy up to ±0.2%
- Various Output: 4-20 mA, digital signals with HART®️ Communication (Modbus RS485)
- Multiple temperature and linearity compensation to improve accuracy
- Fully-sealed and fully isolated silicon pressure sensor
- Superior stainless steel process flange
- Dual diaphragm overload protection, can easily cope with overload tests
- 355° rotation display module
Specifications
Process Medium | Compatible gases, steam and liquids |
Pressure Type | Gauge Pressure |
Process Connection | 1-½” Tri-Clamp or 2″ Tri-Clamp |
Wetted Materials | 316L SS |
Ranges | 5.8 psig to 300 psig |
Accuracy | ±0.2% F.S. |
Stability | ±0.2% URL/5 years |
Working Temperature | -40 °F to 185 °F (-40 °C to 85 °C) |
Insulation Resistance | ≥20 M Ω at 100 VDC |
Mounting Position Effect | Apply to any position. Max value lower than 1.6 w.c. (400 Pa) can be corrected by zero clearing function |
Working Humidity | 5-100% RH |
Net Weight | Approx 3.43 lbs (1.55 Kg) |
Protection class | NEMA 4X(IP66) |
Output Signal | 4 mA to 20 mA with HART (Optional Modbus RS485) |
Standard/flame proof | 10.5-55 VDC |
Load resistance | 0-2119 Ω for working condition, 250- 600 Ω for HART protocol |
Max. Transmission distance | 3281 ft |
Power consumption | ≤500 mW at 24 VDC, 20.8 mA |