DESCRIPTION
Features
NSF
- No moving parts provide easy maintenance.
- Coil assembly is hermetically sealed welded construction.
- Integral or remote transmitter.
- Field interchangeable electronics.
- High linearity.
- Absolute zero stability.
- Eliminates Noise.
- High accuracy and reliability.
- Battery Powered Device.
- Meters batching and blending totalization.
- Self-diagnostic functions.
- No moving parts provide easy maintenance.
- High turndown ratio up to 100:1.
- A backlight LCD display with menu setting control and password protection.
- Auto flow compensation.
- Ensuring empty pipe detection.
- Self-diagnostic functions.
- Ensuring zero-point stability and high reliability.
- Battery Powered Device.
- Meters batching and blending totalization.
Specifications
NSF
Accuracy | ±0.5% (Standard); Optional 0.3% | |
Measuring Range | 0.2 to 12 m/sec Bi-directional | |
Repeatability | ±0.2% of Span | |
Process Pressure | 150# ANSI or 300# ANSI Flange | |
Process Temperature | Integral: -40 to 250°F (-40 to 120°C) Remote: -40 to 350°F (-40 to 180°C) |
|
Operating Temperature | -40°F to 131°F (-40˚C to 55˚C) | |
Operating Humidity | 5-95% RH non-condensing | |
Size | ½” to 28” (10mm to 700mm) | |
Output | 4-20mA, Pulse, HART Modbus RS485 | |
Process Connections | DIN, ANSI Flanges, NPT, Flare, Tri-Clamp | |
Power Supply | 16 to 60VDC or 80 to 300VAC/VDC | |
Protection Class | IP65 (Standard), IP68 (Optional for Flow Tube with Remote Transmitter) |
|
End Connection | Flange | |
Electrode Material | 316 SS | |
Measuring Tube Material | SS304 | |
Housing Material | Carbon Steel | |
Sensor Lining | -300°F to 400°F (-180°C to 200°C) | |
Display Version | Integral or Remote | |
Display Type | 16 characters x 2 row LCD, 5 Digit Flow rate and 8 Digit Totalizer | |
Units | Flow Rate | Totalizer |
LPS, LPM, LPH, LPD Mlps, Mlpm, Mlph, Mlpd cc/s, cc/m, cc/h, cc/d m3/s, m3/m, m3/h, m3/d kg/s, kg/m, kg/h, kg/d t/s, t/m, t/h, t/d gps, gpm, gph, gpd Mgps, Mgpm, Mgph, Mgpd lgps, lgpm, lgph, lgpd lMgps, lMgpm, lMgph, lMgpd ft3/s, ft3/m, ft3/h, ft3/d lb/s, lb/m, lb/h, lb/d |
L, Ml, m3 Ml L, Ml, cc, m3 L, Ml, m3 kg, t T G, ft3 Mg lg, ft3 lMg g, lg, ft3 lb |
|
Cable Length | 15 Ft (Standard), Up to 150 Ft Maximum | |
Terminal Connector | 18 AWG to 22 AWG wire |
Battery Powered
Accuracy | ±0.5% (Standard) | |
Repeatability | ±0.2% of Span | |
Nominal Diameter | 2” to 12” (50 to 300mm) | |
Nominal Pressure | 150# ANSI or 300# ANSI Flange | |
Working Temperature | Direct: -40 to 250°F (-40 to 120°C) Remote: -40 to 350°F (-40 to 180°C) | |
Electrode material | 316 SS | |
Sensor Lining | Polypropylene | |
Display Version | Integral (Optional: Remote) | |
Measuring tube material | SS 304, Carbon Stee | |
Transmitter Material | Die Cast Aluminium | |
End connection | ANSI Flange | |
Flanged Standard | ANSI | |
Measuring Range | 0.7 to 39ft/s (0.2 to 12 m/s) Bidirectional | |
Output | Pulse and RS485 Modbus | |
Power Supply | Battery Powered 5-year Battery Life | |
Protection Class for Sensor | Std. IP65 | |
Protection Class for Transmitter | IP67 | |
Installation | Inline flanged |
TECH DATA
PRODUCT REVIEWS
Product Q & A
Sort By:
No questions yet. Be the first to ask the question!